| ASCII - Command | VOSPD | |||
| Syntax Transmit | VOSPD [Data] | |||
| Syntax Receive | VOSPD <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Float | CANBus Object Number | 3627 (hex) | |
| DIM | rpm | PROFIBUS PNU | 1895 (dec) IND = 1 (dec) | |
| Range | 0.0 .. 1.2*MSPEED | DPR | 295 (dec) | |
| Default | 3600 | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | ||
| Start Firmware | 1.0 | |||
| Configuration | No | Last Change of this Object | 1.0 | |
| Function Group | position loop | EEPROM | Yes | |
| Short Description | Overspeed | |||
Description
| The VOSPD parameter sets the overspeed threshold. As soon as the actual velocity exceeds this limit, the fault message F08 (overspeed) is generated and the output stage is disabled. |