ASCII - Command VSCALE1    
Syntax Transmit VSCALE1 [Data]    
Syntax Receive VSCALE1 <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 3629 (hex)
DIM VUNIT / 10 V   PROFIBUS PNU 1897 (dec) IND = 1 (dec)
Range -16000 .. 16000 (for VUNIT=0)   DPR 297 (dec)
Default 3000 (for VUNIT=0)    
Opmode 1   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 2.10
Function Group analog I/O   EEPROM Yes
Short Description SW1 velocity scaling factor

Description

If the analog input 1 is used as the setpoint input for velocity control, then the VSCALE1 parameter can be used to set the scaling of the input voltage.
A 10V velocity setpoint input at input 1 produces a velocity of VSCALE1.

Attention: VSCALE1/VSCALE2 may not be smaller than 2UPM!