ASCII - Command | VSCALE1 | |||
Syntax Transmit | VSCALE1 [Data] | |||
Syntax Receive | VSCALE1 <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Integer16 | CANBus Object Number | 3629 (hex) | |
DIM | VUNIT / 10 V | PROFIBUS PNU | 1897 (dec) IND = 1 (dec) | |
Range | -16000 .. 16000 (for VUNIT=0) | DPR | 297 (dec) | |
Default | 3000 (for VUNIT=0) | |||
Opmode | 1 | Data Type Bus/DPR | Integer16 | |
Drive State | - | Weighting | ||
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 2.10 | |
Function Group | analog I/O | EEPROM | Yes | |
Short Description | SW1 velocity scaling factor |
Description
If the analog input 1 is used as the setpoint input for velocity control, then the VSCALE1 parameter can be used to set the scaling of the input voltage. A 10V velocity setpoint input at input 1 produces a velocity of VSCALE1. Attention: VSCALE1/VSCALE2 may not be smaller than 2UPM! |