ASCII - Command VWM    
Syntax Transmit VWM [Data]    
Syntax Receive VWM <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer16   CANBus Object Number 3759 (hex)
DIM -   PROFIBUS PNU 1801 (dec) IND = 17 (dec)
Range 0 ... 1500   DPR 601 (dec)
Default 400    
Opmode All   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.35    
Configuration No   Last Change of this Object 1.2
Function Group feedback   EEPROM No
Short Description limit value for SinCos voltage

Description

VWM defines the limit value for n23 warning (SinCos voltage too low). This warning can be used to get a message when a SinCos encoder (linear unit) becomes dirty