ASCII - Command | VWM | |||
Syntax Transmit | VWM [Data] | |||
Syntax Receive | VWM <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Integer16 | CANBus Object Number | 3759 (hex) | |
DIM | - | PROFIBUS PNU | 1801 (dec) IND = 17 (dec) | |
Range | 0 ... 1500 | DPR | 601 (dec) | |
Default | 400 | |||
Opmode | All | Data Type Bus/DPR | Integer16 | |
Drive State | - | Weighting | ||
Start Firmware | 1.35 | |||
Configuration | No | Last Change of this Object | 1.2 | |
Function Group | feedback | EEPROM | No | |
Short Description | limit value for SinCos voltage |
Description
VWM defines the limit value for n23 warning (SinCos voltage too low). This warning can be used to get a message when a SinCos encoder (linear unit) becomes dirty |