Faults which occur, but which do not cause a switch-off of the amplifier output stage (BTB/RTO contact remains closed), are indicated in the LED display on the front panel by a coded warning number.

Some warning messages result in a controlled shut-down of the drive (braking by emergency stop ramp).

The servo amplifier reaction depends on the warning (see STATCODE).

Notes for cause and remedy see Trouble Shooting.

Code

Designation

Explanation

E

Status message

DC-Link voltage ok. Amplifier is enabled.

P

Status message

DC-Link voltage ok. Amplifier is disabled.

. . .

Status message

Amplifier is updating the startup configuration

-

Status message

Status message, no error, programming mode

- S -

Status Message

STO-Enable input is 0V (with disabled drive only)

888

Memory Card

FPGA program not loaded

nd0

Memory Card

Non Dual Use Firmware (labeled with “_ND0") is used.

nd1

Memory Card

An AL-3A225 (ECCN 3A225) export classified Dual Use Firmware (labeled with “_ND1") is used.

n01

I²t

I²t threshold exceeded

n02

regen power

reached preset regen power limit

n03

S_fault

Exceeded preset following error limit

n04

Response monitoring

Response monitoring (fieldbus) has been activated

n05

Supply phase

Mains supply phase missing

n06

SW limit switch 1

Underrun software limit switch 1

n07

SW limit switch 2

Overrun software limit switch 2

n08

Motion task error

A faulty motion task was started

n09

No reference point

No reference point (Home) set at start of motion task

n10

PSTOP

PSTOP limit-switch activated

n11

NSTOP

NSTOP limit-switch activated

n12

Motor default values
loaded

Only for ENDAT/ HIPERFACE: discrepancy between motor number saved in the encoder and the amplifier, motor default values loaded

n13

Expansion card

24V supply of the I/O expansion board is missing

n14

SinCos feedback

SinCos commutation (wake & shake) not completed, will be canceled when amplifier is enabled and wake & shake carried out

n15

Table faults

Speed-Current table INXMODE 35 fault

n16

Summarized warning

Summarized warning for n17 to n31

n17

Fielbus Synchronization

CAN sync is not logged in

n18

Multiturn overrun

Max. number of motor turns exceeded

n19

Motion task ramps are limited

Range overflow on motion task data

n20

Invalid motion task

Invalid motion task

n21

PLC program error

For details see PLC code

n22

Max. motor temperatur reached

The user can shut down the process before the temperature eror will interrupt the process immediately

n23

Sin Cos feedback

Warning level reached

n24

Digital I/O

Configuration is not logical

n25...n31

reserved

reserved

n32

Firmware beta version

Firmware is an unreleased beta version