ASCII - Command ANOFF1    
Syntax Transmit ANOFF1 [Data]    
Syntax Receive ANOFF1 <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 350B (hex)
DIM Millivolts   PROFIBUS PNU 1611 (dec) IND = 1 (dec)
Range -10000 .. 10000   DPR 11 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.8
Function Group Analog I/O   EEPROM Yes
Short Description Analog Offset for input 1

Description

This variable compensates for the offset voltages of CNC controls and the analog input, ANIN1 (1). It can also correct an analog offset from external controls.