ASCII - Command ANOFF2    
Syntax Transmit ANOFF2 [Data]    
Syntax Receive ANOFF2 <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 350C (hex)
DIM Millivolts   PROFIBUS PNU 1612 (dec) IND = 1 (dec)
Range -10000 .. 10000   DPR 12 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.8
Function Group Analog I/O   EEPROM Yes
Short Description Analog Offset for input SW2

Description

This variable compensates for the offset voltages of CNC controls and the analog input, ANIN2 (SW2). It can also correct an analog offset from external controls.