ASCII - Command HVER    
Syntax Transmit HVER    
Syntax Receive HVER <Data>   Available in  
Type Variable ro   MMI Yes
ASCII Format String   CANBus Object Number 3557 (hex)
DIM -   PROFIBUS PNU 1687 (dec) IND = 1 (dec)
Range max 50 ASCII Characters   DPR 87 (dec)
Default -    
Opmode All   Data Type Bus/DPR -
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.3
Function Group Basic Setup   EEPROM No
Short Description Output the Hardware Version

Description

The HVER command returns the designation for the hardware version, in the following form:
“Drive 6xx Hardware Version (yy) zzzz”
xx - designation of the output stage (current rating)
yy - designation of the hardware version
zzzz - date of the first hardware revision