ASCII - Command | INHCMDX | |||
Syntax Transmit | INHCMDX [Data] | |||
Syntax Receive | INHCMDX <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | String | CANBus Object Number | No | |
DIM | - | PROFIBUS PNU | No | |
Range | - | DPR | No | |
Default | ECHO | |||
Opmode | All | Data Type Bus/DPR | - | |
Drive State | - | Weighting | ||
Start Firmware | 1.67 | |||
Configuration | No | Last Change of this Object | 1.3 | |
Function Group | Digital I/O | EEPROM | Yes | |
Short Description | Command buffer for high level (INxMODE=31,34) |
Description
The command INHCMDX can be used to define an ASCII command sequence. This command sequence will always be carried out when a rising edge is detected at the input that has been configured with the function INxMODE=31,34 A command sequence consists of individual ASCII commands, separated by a semicolon (;) The maximum length of this command sequence is 56 characters. Example: INHCMDX GV 10; GVTN 15 If a LOW/HIGH edge is detected, the gain of the velocity control loop is set to 10 and the integral action time is set to 15 msec. |