| ASCII - Command | ISCALE2 | |||
| Syntax Transmit | ISCALE2 [Data] | |||
| Syntax Receive | ISCALE2 <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Float | CANBus Object Number | 3572 (hex) | |
| DIM | A/10Volts | PROFIBUS PNU | 1714 (dec) IND = 1 (dec) | |
| Range | 0.0 .. 100.0 | DPR | 114 (dec) | |
| Default | DIPEAK | |||
| Opmode | 3 | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | 1000 | |
| Start Firmware | 1.20 | |||
| Configuration | No | Last Change of this Object | 1.3 | |
| Function Group | Analog I/O | EEPROM | Yes | |
| Short Description | Scaling of Analog Current command 2 | |||
Description
| Defines the scaling for the analog command input SW2 (if it is a current command in OPMODE = 3). The current value that is set here corresponds to the maximum input voltage (10V). |