ASCII - Command | MAXTEMPM | |||
Syntax Transmit | MAXTEMPM [Data] | |||
Syntax Receive | MAXTEMPM <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Float | CANBus Object Number | 3586 (hex) | |
DIM | Ohm (KOhm) | PROFIBUS PNU | 1734 (dec) IND = 1 (dec) | |
Range | 0.0 .. 6000.0 | DPR | 134 (dec) | |
Default | 291 | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 2.49 | |||
Configuration | No | Last Change of this Object | 1.6 | |
Function Group | Basic Setup | EEPROM | Yes | |
Short Description | Motor Temperature Switch off Threshold |
Description
The motor temperature for turning off the power stage (disabling the drive) and displaying a F06 fault. Firmware <2.49 (units = ohms)Entry in ohms up to 6000 (6000 corresponds to about 800 ohms in reality).Firmware 2.49 or above (units = kohms)Entry in kilohms up to 1.5 (1.5 corresponds to about 1500 ohms in reality).If an amplifier is updated to version 2.49 or higher, the resistance value is automatically converted from ohms to kohms. |