ASCII - Command MAXTEMPM    
Syntax Transmit MAXTEMPM [Data]    
Syntax Receive MAXTEMPM <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Float   CANBus Object Number 3586 (hex)
DIM Ohm (KOhm)   PROFIBUS PNU 1734 (dec) IND = 1 (dec)
Range 0.0 .. 6000.0   DPR 134 (dec)
Default 291    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 2.49    
Configuration No   Last Change of this Object 1.6
Function Group Basic Setup   EEPROM Yes
Short Description Motor Temperature Switch off Threshold

Description

The motor temperature for turning off the power stage (disabling the drive) and displaying a F06 fault. Firmware <2.49 (units = ohms)Entry in ohms up to 6000 (6000 corresponds to about 800 ohms in reality).Firmware 2.49 or above (units = kohms)Entry in kilohms up to 1.5 (1.5 corresponds to about 1500 ohms in reality).If an amplifier is updated to version 2.49 or higher, the resistance value is automatically converted from ohms to kohms.