ASCII - Command MCTR    
Syntax Transmit MCTR [Data]    
Syntax Receive MCTR <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 366A (hex)
DIM -   PROFIBUS PNU 1962 (dec) IND = 1 (dec)
Range 1 ... 5   DPR 362 (dec)
Default 1.1    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 3.40    
Configuration No   Last Change of this Object 1.6
Function Group Motor   EEPROM Yes
Short Description Correction Factor of the rotor time constant

Description

This command is only for the induction motor mode (MTYPE = 3).
The correction factor of the rotor time constant for the field weakening, which is introduced to improve the torque performance at the steady state in the field weakening.