| ASCII - Command | MCTR | |||
| Syntax Transmit | MCTR [Data] | |||
| Syntax Receive | MCTR <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Float | CANBus Object Number | 366A (hex) | |
| DIM | - | PROFIBUS PNU | 1962 (dec) IND = 1 (dec) | |
| Range | 1 ... 5 | DPR | 362 (dec) | |
| Default | 1.1 | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | 1000 | |
| Start Firmware | 3.40 | |||
| Configuration | No | Last Change of this Object | 1.6 | |
| Function Group | Motor | EEPROM | Yes | |
| Short Description | Correction Factor of the rotor time constant | |||
Description
| This command is only for the induction motor mode (MTYPE = 3). The correction factor of the rotor time constant for the field weakening, which is introduced to improve the torque performance at the steady state in the field weakening. |