ASCII - Command MIMR    
Syntax Transmit MIMR [Data]    
Syntax Receive MIMR <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 366B (hex)
DIM A   PROFIBUS PNU 1963 (dec) IND = 1 (dec)
Range (0.0 ... 0.8) * ICONT   DPR 363 (dec)
Default 0.0    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 3.40    
Configuration No   Last Change of this Object 1.9
Function Group Motor   EEPROM Yes
Short Description Magnetizing Current (Induction Motor)

Description

This command is only for the induction motor mode (MTYPE = 3).
The MIMR defines the magnetizing current of induction motors, which is normally set in the range of 40%~50% of the rated current of the induction motor.
The magnetizing current maintains constant under the rated velocity. If the motor runs over the rated velocity, the magnetizing current will be decreased according to the rotor mechanical velocity.
This value will be also limited between 10% and 80% of the rated current.