ASCII - Command MSG    
Syntax Transmit MSG [Data]    
Syntax Receive MSG <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer8   CANBus Object Number 35A2 (hex)
DIM -   PROFIBUS PNU 1762 (dec) IND = 1 (dec)
Range 0, 1, 2   DPR 162 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer8
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.3
Function Group Communication   EEPROM Yes
Short Description Enable / Disable All Messages via RS232

Description

If “MSG 2” is set, then the execution of the individual initialization steps will be signaled through the serial interface when the amplifier is switched on (initialization phase). This setting should only be used for test purposes (e.g. during commissioning). Since the PC operating program basically only works with the setting “MSG 1”, the “MSG 2” setting can only be implemented with the help of a terminal program (not in the terminal window of the operating program).