ASCII - Command MTANGLP    
Syntax Transmit MTANGLP [Data]    
Syntax Receive MTANGLP <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 35A5 (hex)
DIM Electrical Degrees   PROFIBUS PNU 1765 (dec) IND = 1 (dec)
Range 0 .. 45   DPR 165 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.8
Function Group Motor   EEPROM Yes
Short Description Current Lead

Description

The current-dependent phase lead that is applied to make use of the reluctance torque at motor peak current (MIPEAK.