| ASCII - Command | MTANGLP | |||
| Syntax Transmit | MTANGLP [Data] | |||
| Syntax Receive | MTANGLP <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Integer16 | CANBus Object Number | 35A5 (hex) | |
| DIM | Electrical Degrees | PROFIBUS PNU | 1765 (dec) IND = 1 (dec) | |
| Range | 0 .. 45 | DPR | 165 (dec) | |
| Default | 0 | |||
| Opmode | All | Data Type Bus/DPR | Integer16 | |
| Drive State | - | Weighting | ||
| Start Firmware | 1.20 | |||
| Configuration | No | Last Change of this Object | 1.8 | |
| Function Group | Motor | EEPROM | Yes | |
| Short Description | Current Lead | |||
Description
| The current-dependent phase lead that is applied to make use of the reluctance torque at motor peak current (MIPEAK. |