ASCII - Command MTR    
Syntax Transmit MTR [Data]    
Syntax Receive MTR <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 366C (hex)
DIM ms   PROFIBUS PNU 1964 (dec) IND = 1 (dec)
Range 30 .. 1000   DPR 364 (dec)
Default 200    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 3.40    
Configuration No   Last Change of this Object 1.4
Function Group Motor   EEPROM Yes
Short Description Rotor Time Constant

Description

This command is only for the induction motor mode (MTYPE = 3).
The MTR defines the rotor time constant at the rated operating point (Tr = Lh/Rr), where Lh and Rr are the magnetizing inductance and rotor resistance, respectively.