ASCII - Command PBALMAX    
Syntax Transmit PBALMAX [Data]    
Syntax Receive PBALMAX <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer32   CANBus Object Number 35C1 (hex)
DIM W   PROFIBUS PNU 1793 (dec) IND = 1 (dec)
Range see Manual   DPR 193 (dec)
Default 80 / 200    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.6
Function Group Basic Setup   EEPROM Yes
Short Description Maximum Regen Power

Description

This parameter can be used to limit the continuous power dissipated in the regen resistor.
If the actual value of the power in the regen resistor exceeds the preset maximum value, then the regen resistor is switched off. This may trigger the fault message “Overvoltage” as a result. If the maximum value is too high, the regen resistor may be overloaded.