| ASCII - Command | PMODE | |||
| Syntax Transmit | PMODE [Data] | |||
| Syntax Receive | PMODE <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Integer8 | CANBus Object Number | 35CD (hex) | |
| DIM | - | PROFIBUS PNU | 1805 (dec) IND = 1 (dec) | |
| Range | 0, 1, 2 | DPR | 205 (dec) | |
| Default | 1 | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | Disabled + Reset (Coldstart) | Weighting | ||
| Start Firmware | 1.20 | |||
| Configuration | Yes | Last Change of this Object | 1.3 | |
| Function Group | Basic Setup | EEPROM | Yes | |
| Short Description | Line Phase Error Mode | |||
Description
| The PMODE parameter configures the response of the amplifier to the failure of a mains supply phase. PMODE=0 no warning, no fault message, current limited to max. 4A PMODE=1 warning n05, current limited to max. 4A PMODE=2 fault message F19, output stage is disabled If the current limiting is activated, it only applies to periods of acceleration. A braking operation can still be carried out at full current. |