Screen page "PROFIBUS"
The PROFIBUS-specific parameters, the bus status, and the data words in the transmit and receive directions, as seen by the bus-master are displayed on this screen page. This page is helpful when searching for errors and commissioning the bus communication.
Baudrate
The baud rate that is given by the PROFIBUS master is shown here.
PNO Identification
The PNO identification is the number for servoamplifier in the list of
ID-numbers of the PROFIBUS user organization.
Address
Station address of the amplifier. The address is set up on the screen page
“Basic setup”.
PPO Type
The servoamplifier only supports PPO-type 2 of the PROFIDRIVE profile.
BUS status
Shows the present status of the bus communication. Data can only be transferred
across the PROFIBUS when the "Communication OK" message appears.
Input/Output-Buffer
The data for input/output are only transferred, if the threshold monitoring for the servoamplifier has been activated in the masters hardware configuration.
Output
The last bus object that was received by the master.
Input
The last bus object that was sent by the master.