ASCII - Command REFIP2    
Syntax Transmit      
Syntax Receive   Available in  
Type Variable rw   MMI No
ASCII Format Float32   CANBus Object Number 36E3 (hex)
DIM     PROFIBUS PNU 1683 (dec) IND = 17 (dec)
Range 0 ...IPEAK   DPR 483 (dec)
Default IPEAK    
Opmode     Data Type Bus/DPR  
Drive State     Weighting  
Start Firmware 5.8    
Configuration No   Last Change of this Object 1.0
Function Group     EEPROM  
Short Description

Description

REFIP2 limits the peak current during the wake & shake procedure.
After wake & shake is finished the current is reset to the IPEAK value.