ASCII - Command | SSIGRAY | |||
Syntax Transmit | SSIGRAY [Data] | |||
Syntax Receive | SSIGRAY <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Integer8 | CANBus Object Number | 35F6 (hex) | |
DIM | - | PROFIBUS PNU | 1846 (dec) IND = 1 (dec) | |
Range | 0, 1 | DPR | 246 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer8 | |
Drive State | Disabled | Weighting | ||
Start Firmware | 1.20 | |||
Configuration | No | Last Change of this Object | 2.0 | |
Function Group | Feedback | EEPROM | Yes | |
Short Description | Select SSI Code |
Description
The SSIGRAY command can be used to define the format to be used for the output of the SSI information on connector X5 (Drive 400 X4). SSIGRAY=0 binary code SSIGRAY=1 Gray code |