ASCII Objekt-Reference 

 

Home 

Screen Page "SERCOS" 



Address 

ASCII: ADDR 

Default: 0 

valid for all OPMODES 

The address mark the Sercos station address of the drive, within the Sercos communication The address can changed between 0 and 63 in the screen "Basic settings".
Address 0 designates the drive as a repeater on the Sercos ring.
 


Baud Rate 

ASCII: SBAUD 

Default: 4MBaud 

valid for all OPMODES 

In this field it is possible to set the Sercos baud rate.
 


LWL-Length 

ASCII: SLEN 

Default: 5m 

valid for all OPMODES 

Within this parameter it is possible to change the optical power of the transmit output of the drive, to the next station in the ring. The optical power can set for the length of plastic optical cable, in meters, from 1 to 45 meters. If the optical power is not adjusted properly, there will be errors in the telegram transmission, and the red error LED on the drive will light. In normal communication, the green transmit and receive LED’s will light (referring to the LED of the optical transmission).
 


Phase 

ASCII: SPHAS 

Default: - 

valid for all OPMODES 

This field display the actual phase of the Sercos communication.
 


Status 

ASCII: SSTAT 

Default: - 

valid for all OPMODES 

This field displays the actual status of the Sercos communication, according the Sercos status-word in text format.
 


SERCOS SERVICE 

With this button you can open the "Sercos Service" screen page.