ASCII - Command TRUN    
Syntax Transmit TRUN    
Syntax Receive TRUN <Data>   Available in  
Type Variable ro   MMI Yes
ASCII Format String   CANBus Object Number (hex)
DIM hhhhh:mm   PROFIBUS PNU (dec) IND = 17 (dec)
Range 00000:00 to 99999:45   DPR (dec)
Default -    
Opmode All   Data Type Bus/DPR -
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.9
Function Group Basic Setup   EEPROM Yes
Short Description Run-time counter

Description

The run-time counter shows the operating life of the amplifier (if the 24V is applied) in minutes.
The internal resolution of the run-time counter is 1 second.
Since the run-time counter value is included in the serial EEPROM of the amplifier, it is only updated in the EEPROM every 8 minutes So switching off the 24V supply can cause a loss in the record of up to 8 minutes.