ASCII - Command | VOSPD | |||
Syntax Transmit | VOSPD [Data] | |||
Syntax Receive | VOSPD <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Float | CANBus Object Number | 3627 (hex) | |
DIM | rpm | PROFIBUS PNU | 1895 (dec) IND = 1 (dec) | |
Range | 0.0 .. 1.2*MSPEED | DPR | 295 (dec) | |
Default | 3600 | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.20 | |||
Configuration | No | Last Change of this Object | 1.3 | |
Function Group | Velocity Controller | EEPROM | Yes | |
Short Description | Overspeed |
Description
The VOSPD parameter sets the overspeed threshold. As soon as the actual velocity exceeds this limit, the fault message F08 (overspeed) is generated and the output stage is disabled. |