ASCII - Command VSCALE1    
Syntax Transmit VSCALE1 [Data]    
Syntax Receive VSCALE1 <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 3629 (hex)
DIM ( >VUNIT )   PROFIBUS PNU 1897 (dec) IND = 1 (dec)
Range -15000 .. 15000   DPR 297 (dec)
Default 3000    
Opmode 1   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.8
Function Group Analog I/O   EEPROM Yes
Short Description analog input 1 Velocity Scaling Factor

Description

If the analog input 1 is used as the command input for velocity control, then the VSCALE1 parameter can be used to set the scaling of the input voltage.
A 10V velocity command input at input analog input 1 produces a velocity of VSCALE1.