| ASCII - Command | VSCALE1 | |||
| Syntax Transmit | VSCALE1 [Data] | |||
| Syntax Receive | VSCALE1 <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Integer16 | CANBus Object Number | 3629 (hex) | |
| DIM | ( >VUNIT ) | PROFIBUS PNU | 1897 (dec) IND = 1 (dec) | |
| Range | -15000 .. 15000 | DPR | 297 (dec) | |
| Default | 3000 | |||
| Opmode | 1 | Data Type Bus/DPR | Integer16 | |
| Drive State | - | Weighting | ||
| Start Firmware | 1.20 | |||
| Configuration | No | Last Change of this Object | 1.8 | |
| Function Group | Analog I/O | EEPROM | Yes | |
| Short Description | analog input 1 Velocity Scaling Factor | |||
Description
| If the analog input 1 is used as the command input for velocity control, then the VSCALE1 parameter can be used to set the scaling of the input voltage. A 10V velocity command input at input analog input 1 produces a velocity of VSCALE1. |