Screen layout
|
Title Bar
The program name, station address, and the name of the currently valid
data set (amplifier) are displayed in the title bar.
During offline operation,
instead of the station address a number above 100 will be shown, possibly
with the storage location (folder + file name) of the data set that has
been loaded.
Toolbar
The typical Windows-style buttons can be used for a direct start of individual
functions.
Status Bar
Current information about the data communication is shown here.
Menu bar
FILE |
|
Open |
A parameter and/or motion task data set is read from the data medium (hard disk, diskette) and becomes the currently valid set. The servo amplifier must be disabled to do this. |
Close |
The current data set is closed and not saved. |
Save |
Saves the current parameter or motion task data set to a data medium (hard disk, diskette) while keeping the file name, if the data set already has a name. If the data set has not yet got a name, you will be prompted to enter a name and storage location. You can save parameters and motion task data to one single file or to separate files. |
Save as |
Saves the current parameter or motion task data set to a data medium (hard disk, diskette). You will be prompted to enter a name and storage location. |
|
The current data set will be printed out. You can choose whether the print data are sent to the system printer or saved to a file. |
Print preview / Print setup |
Use these functions in the same way as for any other Windows software. |
Exit |
Terminates the program. |
COMMUNICATION |
|
COM1...COM10 |
If one of these interfaces (ports) is available for communication with a servo amplifier, which means that it is not used by other equipment or drivers, then the text label appears in full black and can be selected. Select this interface and use it for the connection to the servo amplifier |
Offline |
You can still work with the setup software, even if there is no servo amplifier connected. You can load a set of data from the hard disk (diskette), work on it, and save it again. The software functions and screen pages that only have a use in the online mode will not be selectable. |
Disconnect interfaces |
This deactivates the access to the setup software from interfaces COM1 to COM10. This function is important if, for instance, the servo amplifier is to be accessed from an external program, without closing the setup software. |
Multidrive |
With this function, you can establish connection to other amplifiers, that are connected via the CAN-bus with the amplifier that communicates via the RS232-interface with the PC. Therefore, all devices must have different addresses.This function should not be used in running field bus applications. |
Update active window only |
This affects the updating of the actual-value display in open windows. activated: only the active window will be updated de-activated: the actual values will be continuously updated in all open windows, but this is detrimental for keeping the active display up to date. |
Lower Transmission Priority |
Delay of serial communication in favor of the data communication over a field bus. |
TOOLS |
|
Terminal, Monitor, Oscilloscope, Drive status |
Opens the corresponding screen page |
EDIT |
|
Undo, Cut, Copy, Paste |
Use these functions in the same way as for any other Windows software. |
VIEW |
|
Toolbar / Status bar |
Switch to insert the toolbar (above) or the status bar (below) into the screen. |
Window |
|
Cascade / Tile vertically / Arrange icons |
Use these function in the same way as for any other Windows software. |
SERVICE |
|
STOP (F9) |
Brakes off the drive movement. The response of the drive varies according to the operating mode that is valid at the moment: OPMODE=0 the drive brakes along the preset braking ramp for the speed control loop (DEC) OPMODE=2 the drive coasts down
OPMODE=8 breaks off the present motion task. The drive brakes along the
braking ramp that is If the screen "Oscilloscope/Service" is active, you can also start the service function from here. |
? (Help function) |
Opens the HTML help file |