ASCII - Command | GF | |||
Syntax Transmit | GF [Data] | |||
Syntax Receive | GF <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Float | CANBus Object Number | - | |
DIM | - | PROFIBUS PNU | - | |
Range | 0 ... 10 | DPR | No | |
Default | 1 | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.37 | |||
Configuration | No | Last Change of this Object | 2.7 | |
Function Group | other commands | EEPROM | Yes | |
Short Description | proportional gain of the flux controller |
Description
GF is a parameter for the base speed range of the induction maschine. The default values for GF respectively for GF 1ms. Normally, they can be left at these values, as the rotor's flow only reacts very slowly. Please have a look to GFTN |