ASCII - Command GFTN    
Syntax Transmit GFTN [Data]    
Syntax Receive GFTN <Data>   Available in  
Type Variable rw   MMI No
ASCII Format -   CANBus Object Number 3907 (hex)
DIM ms   PROFIBUS PNU 1831 (dec) IND = 33 (dec)
Range 1 .. 32000   DPR No
Default 150    
Opmode All   Data Type Bus/DPR -
Drive State -   Weighting  
Start Firmware 1.37    
Configuration No   Last Change of this Object 2.11
Function Group other commands   EEPROM Yes
Short Description time constant flow controlinduction maschine)

Description

GFTN is a parameter for the base speed range of the induction maschine. The default values for GF respectively for GFTN 150ms. Normally, they can be left at these values, as the rotor's flow only reacts very slowly.

Please have a look to GF