ASCII - Command GP2    
Syntax Transmit GP2 [Data]    
Syntax Receive GP2 <Data>   Available in  
Type Variable rw   MMI No
ASCII Format -   CANBus Object Number 38C3 (hex)
DIM VUNIT   PROFIBUS PNU 1763 (dec) IND = 33 (dec)
Range 0 .. 1000   DPR 963 (dec)
Default 0.1    
Opmode All   Data Type Bus/DPR -
Drive State -   Weighting  
Start Firmware      
Configuration No   Last Change of this Object 2.10
Function Group position loop   EEPROM Yes
Short Description proportional gain for the velocity higher than GPS2

Description

GP2 is a paramter of th position loop and is the proportional gain for the velocity higher than GPS2

If the parameters (GP=GP2) are eqaul, the interpolation is switched off which is the case by default. As long as they are equal, a change of GP leads to an automatic change of GP2, so that they remain the same. Only when GP2 is set once at a value other than GP, pairing is dissolved and both parameters can be modified separately. By setting GP2 to GP parameter coupling is activated again.

Who does not need the interpolation function and only use GP, the existence of GP2 will not even notice.