ASCII - Command MCFW    
Syntax Transmit MCFW [Data]    
Syntax Receive MCFW <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Float   CANBus Object Number 3908 (hex)
DIM -   PROFIBUS PNU 1832 (dec) IND = 33 (dec)
Range 1 .. 2   DPR 1032 (dec)
Default 1    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting  
Start Firmware 3.00    
Configuration No   Last Change of this Object 2.1
Function Group other commands   EEPROM Yes
Short Description The Correction Factor of the Field Weakening

Description

This command is only for the induction motor mode (MTYPE = 3).
The correction factor of the field weakening.
This correction factor is introduced to compensate the nonlinearity of the magnetizing inductance since the magnetizing current is decreased according to the rotor mechanical velocity during the field weakening.