ASCII - Command MIMR    
Syntax Transmit MIMR [Data]    
Syntax Receive MIMR <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 366B (hex)
DIM A   PROFIBUS PNU 1963 (dec) IND = 1 (dec)
Range variable   DPR 363 (dec)
Default variable    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.37    
Configuration No   Last Change of this Object 2.13
Function Group other commands   EEPROM Yes
Short Description current command D-part

Description

If a asynchron motor is used MTYPE = 3 a D-part for the current is sticked in.