ASCII - Command MTAB    
Syntax Transmit MTAB [Data]    
Syntax Receive MTAB <Data>   Available in  
Type Variable rw   MMI No
ASCII Format -   CANBus Object Number -
DIM Ohm   PROFIBUS PNU -
Range     DPR No
Default      
Opmode All   Data Type Bus/DPR -
Drive State     Weighting  
Start Firmware 5.45    
Configuration No   Last Change of this Object 2.8
Function Group motor   EEPROM Yes
Short Description Enter the KTY characteristics

Description

With the syntax: MTAB Temp1 R1 Temp2 R2…Temp10 R10 defines the required characteristic curve

Temp1..10 : temperature in arbitrary value X
R1...R10: Resistor in Ohm

The number of points for the temperature characteristics must be 2 to 10. Internally, there will be a linear interpolation between the points. To delete the curve, type in MTAB 0 0

In a non-existent characteristic MTAB the command returns no values??. If the characteristic is not defined, then the temperature display TEMPM and the temperature error threshold MAXTEMPM appears as a resistance in ohms.

For existing characteristic MTAB the units change for the parameters MAXTEMPM and TEMPM from ohms to unit X

Please have a look to: TEMPM und MAXTEMPM