ASCII - Command MVR    
Syntax Transmit MVR [Data]    
Syntax Receive MVR <Data>   Available in  
Type     MMI No
ASCII Format -   CANBus Object Number 366D (hex)
DIM     PROFIBUS PNU 1965 (dec) IND = 1 (dec)
Range 0 .. MSPEED   DPR 365 (dec)
Default 0    
Opmode     Data Type Bus/DPR -
Drive State     Weighting  
Start Firmware      
Configuration No   Last Change of this Object 2.13
Function Group other commands   EEPROM  
Short Description Nominal speed of asynchron motor

Description

Rated speed of the induction motor.

Significance depends on mode of operation:

1. Normal operation of the induction machine (with sensor): (DRVCNFG2 Bit 0x8000000=1)
MVR defines the beginning of field for the induction machine. Above this speed, the nominalD-current (MIMR) is lowered. MVR = 0 disables field weakening

2. V/f control (no sensor): (DRVCNFG2 Bit 0x8000000=0)
Used to calculate V/f trajectory.