ASCII - Command SWCNFG    
Syntax Transmit SWCNFG [Data]    
Syntax Receive SWCNFG <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Unsigned16   CANBus Object Number 3600 (hex)
DIM -   PROFIBUS PNU 1856 (dec) IND = 1 (dec)
Range 0 .. 65535   DPR 256 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Unsigned16
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 1.0    
Configuration Yes   Last Change of this Object 1.0
Function Group position loop   EEPROM Yes
Short Description Configuration of software limit switches

Description

Configuration of software limit switches

The SWCNFG variable can be considered as a bit-variable. The individual bits are interpreted as follows:

Bit 0 =1 Software limit switch 1 active
Bit 1 =1 Software limit switch 2 active

The software limit sitches are acting only after a homing is done.

see also SWE1, SWE2