ASCII - Command | T | |||
Syntax Transmit | T [Data] | |||
Syntax Receive | T <Data> | Available in | ||
Type | Command | MMI | Yes | |
ASCII Format | Float | CANBus Object Number | 360E (hex) | |
DIM | A | PROFIBUS PNU | 1870 (dec) IND = 1 (dec) | |
Range | -DIPEAK .. DIPEAK | DPR | 270 (dec) | |
Default | - | |||
Opmode | 2 | Data Type Bus/DPR | Integer32 | |
Drive State | Enabled | Weighting | 1000 | |
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 1.0 | |
Function Group | current loop | EEPROM | No | |
Short Description | Digital current setpoint |
Description
The “T” command can be used to define a constant current setpoint <i> (in A). This current setpoint remains effective until a new T / STOP / OPMODE command is executed. |