ASCII - Command AUTOHOME    
Syntax Transmit AUTOHOME [Data]    
Syntax Receive AUTOHOME <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer8   CANBus Object Number 36D7 (hex)
DIM   PROFIBUS PNU 1671 (dec) IND = 17 (dec)
Range 0,1   DPR 471 (dec)
Default 0    
Opmode 8, 4   Data Type Bus/DPR Integer8
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 1.0    
Configuration Yes   Last Change of this Object 1.0
Function Group position loop   EEPROM Yes
Short Description Automatic homing

Description

The Command AUTOHOME selects, if the homing procedure will be started automatic.


AUTOHOME=0 no automatic homing prcedure started

AUTOHOME=1 After the drive is enabled the homing procedure MH is started automatic

FW > 1.31
AUTOHOME=2 After the drive is enabled the homing procedure MH is started automatic, in case it was not already set .