ASCII - Command CLRWARN    
Syntax Transmit CLRWARN [Data]    
Syntax Receive CLRWARN <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Unsigned8   CANBus Object Number 351B (hex)
DIM -   PROFIBUS PNU 1627 (dec) IND = 1 (dec)
Range 0, 1   DPR 27 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Unsigned8
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 3.18    
Configuration Yes   Last Change of this Object 2.1
Function Group drive configuration   EEPROM Yes
Short Description Warning mode

Description

The CLRWARN configuration variable can be used to control the response of the drive if a warning occurs.

CLRWARN=0 Warnings will be displayed until the cause of the warning has been removed.
Warnings cannot be cancelled (exceptions: - contouring/following error, threshold detection).
CLRWARN=1 A warning is only displayed at the moment when it occurs (transition).
All warnings can be cancelled by the CLRFAULT command, or through the digital input (“Controller reset” function).

The listing of the possible warnings can be found in the description of the STATCODE * command.