| ASCII - Command | MAXVSETP | |||
| Syntax Transmit | MAXVSETP [Data] | |||
| Syntax Receive | MAXVSETP <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Float | CANBus Object Number | 38B4 (hex) | |
| DIM | PROFIBUS PNU | 1748 (dec) IND = 33 (dec) | ||
| Range | 0 .. 16000 | DPR | 948 (dec) | |
| Default | 0 | |||
| Opmode | All | Data Type Bus/DPR | - | |
| Drive State | Weighting | |||
| Start Firmware | ||||
| Configuration | No | Last Change of this Object | 2.7 | |
| Function Group | position loop | EEPROM | ||
| Short Description | Limitation of the proportional part of the position loop | |||
Description
| The proportional and integral part of the position loop can be saturated with the parameters MAXVSETP and MAXISETP. MAXVSETP: limit for the proportional part of the position loop (in RPM) The value of 0 (default) means - no limitation |