| ASCII - Command | SSITIME | |||
| Syntax Transmit | SSITIME [Data] | |||
| Syntax Receive | SSITIME <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Integer8 | CANBus Object Number | 390B (hex) | |
| DIM | µsec | PROFIBUS PNU | 1835 (dec) IND = 33 (dec) | |
| Range | 1 ... 15 | DPR | 1035 (dec) | |
| Default | 10 | |||
| Opmode | All | Data Type Bus/DPR | Integer8 | |
| Drive State | Disabled + Reset (Coldstart) | Weighting | ||
| Start Firmware | 5.87 | |||
| Configuration | Yes | Last Change of this Object | 2.10 | |
| Function Group | feedback | EEPROM | Yes | |
| Short Description | SSI setting time | |||
Description
| This parameter set the SSI settling time at SSITOUT = 3 |