| ASCII - Command | SSITOUT | |||
| Syntax Transmit | SSITOUT [Data] | |||
| Syntax Receive | SSITOUT <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Integer8 | CANBus Object Number | 3661 (hex) | |
| DIM | - | PROFIBUS PNU | 1953 (dec) IND = 1 (dec) | |
| Range | 0 .. 3 | DPR | 353 (dec) | |
| Default | 0 | |||
| Opmode | All | Data Type Bus/DPR | Integer8 | |
| Drive State | Disabled + Reset (Coldstart) | Weighting | ||
| Start Firmware | 1.0 | |||
| Configuration | Yes | Last Change of this Object | 2.10 | |
| Function Group | feedback | EEPROM | Yes | |
| Short Description | Transmit setting time SSI | |||
Description
| The command SSIOUT sets the monoflop - setting time of the SSI - transmittion. SSI - OUTPUT: SSITOUT = 0 <= setting time 13 µsec SSITOUT = 1 <= setting time 3 µsec since FW 5.87: SSITOUT = 2 <= setting time 8 µsec SSITOUT = 3 <= free programmable settling time (input via the parameter SSITIME) SSI - INPUT: This parameter defines the clock-frequency, which is used for the read of the SSI-data word. SSITOUT 0: 1MHz only for 1. & 2. feedback (FBTYPE, EXTPOS) SSITOUT 1: 500 kHz only for 1. & 2. feedback (FBTYPE, EXTPOS) SSITOUT 2: 250 kHz only for second feedback (EXTPOS) SSITOUT 3: 125 kHz only for second feedback (EXTPOS) |