ASCII - Command | ADDRFB | |||
Syntax Transmit | ADDRFB [Data] | |||
Syntax Receive | ADDRFB <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Integer16 | CANBus Object Number | 369C (hex) | |
DIM | - | PROFIBUS PNU | 2012 (dec) IND = 1 (dec) | |
Range | 0 .. 63 | DPR | 412 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer16 | |
Drive State | - | Weighting | ||
Start Firmware | 4.91 | |||
Configuration | No | Last Change of this Object | 1.6 | |
Function Group | Communication | EEPROM | Yes | |
Short Description | Fieldbus address at Drive 400 Slave |
Description
ADDRFB defines the fieldbus address of the SERVOSTAR 400 for CAN/PROFIBUS and Sercos. After changing the parameter, a parameter save (SAVE) has to be initiated and the drive has to be reset. This address is used only for the external Bus communication. The serial communication uses still the address given by ADDR. If ADDRFB = 0, the internal address ADDR is used. |