ASCII - Command AN11RANGE    
Syntax Transmit AN11RANGE [Data]    
Syntax Receive AN11RANGE <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer32   CANBus Object Number 369A (hex)
DIM -   PROFIBUS PNU 2010 (dec) IND = 1 (dec)
Range -262144 .. 262143   DPR 410 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting  
Start Firmware 4.78    
Configuration No   Last Change of this Object 1.6
Function Group Analog I/O   EEPROM Yes
Short Description Range of the analog change of INxTRIG

Description

The parameter AN11RANGE gives the change of IN1TRIG, IN2TRIG, IN3TRIG or IN4TRIG, that is caused by an analog input 2 step from 0V to 10V. The function is supported using ANCNFG=11 and ANCNFG=12.

Example:

ANCNFG=11
AN11NR=1
IN1TRIG=1000
AN11RANGE=500

at Analog input2 = 0V IN1TRIG = 1000
at Analog input2 = 10V IN1TRIG = 1500
at Analog input2 = -10V IN1TRIG = 500