ASCII - Command DICONT    
Syntax Transmit DICONT    
Syntax Receive DICONT <Data>   Available in  
Type Variable ro   MMI Yes
ASCII Format Float   CANBus Object Number 3527 (hex)
DIM Amperes   PROFIBUS PNU 1639 (dec) IND = 1 (dec)
Range 1.5 .. 20.0   DPR 39 (dec)
Default Hardware Defined    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.3
Function Group Amplifier   EEPROM No
Short Description Drive Continuous Current

Description

The continuous current rating of the drive. DICONT is depending on VBUSBAL for drive 403 und 406. The drive 614 shows 20A, because the same power module as 620 is used.