ASCII - Command | DICONT | |||
Syntax Transmit | DICONT | |||
Syntax Receive | DICONT <Data> | Available in | ||
Type | Variable ro | MMI | Yes | |
ASCII Format | Float | CANBus Object Number | 3527 (hex) | |
DIM | Amperes | PROFIBUS PNU | 1639 (dec) IND = 1 (dec) | |
Range | 1.5 .. 20.0 | DPR | 39 (dec) | |
Default | Hardware Defined | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.20 | |||
Configuration | No | Last Change of this Object | 1.3 | |
Function Group | Amplifier | EEPROM | No | |
Short Description | Drive Continuous Current |
Description
The continuous current rating of the drive. DICONT is depending on VBUSBAL for drive 403 und 406. The drive 614 shows 20A, because the same power module as 620 is used. |