ASCII - Command GF   For Manufacturer Use only
Syntax Transmit GF [Data]    
Syntax Receive GF <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 3667 (hex)
DIM -   PROFIBUS PNU 1959 (dec) IND = 1 (dec)
Range 0 ... 2000   DPR 359 (dec)
Default 15    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 3.40    
Configuration No   Last Change of this Object 1.4
Function Group Motor   EEPROM Yes
Short Description Proportional Gain of the Flux Controller

Description

This command is only for the induction motor mode (MTYPE = 3).
This rotor flux controller utilizes a standard PI controller.
Rotor flux control loop: propotional gain. (3.40) (see also GFTN)