ASCII - Command GFTN   For Manufacturer Use only
Syntax Transmit GFTN [Data]    
Syntax Receive GFTN <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 3668 (hex)
DIM ms   PROFIBUS PNU 1960 (dec) IND = 1 (dec)
Range 0 ... 1000   DPR 360 (dec)
Default 50    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 3.40    
Configuration No   Last Change of this Object 1.4
Function Group Motor   EEPROM Yes
Short Description Integral Action Time of the Flux Controller

Description

This command is only for the induction motor mode (MTYPE = 3).
This rotor flux controller utilizes a standard PI controller.
Rotor flux control loop: integral action time constant. (3.40) (see also GF)