ASCII - Command ICONT    
Syntax Transmit ICONT [Data]    
Syntax Receive ICONT <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Float   CANBus Object Number 355C (hex)
DIM Amperes   PROFIBUS PNU 1692 (dec) IND = 1 (dec)
Range 10% of DICONT, max(DICONT,IPEAK)   DPR 92 (dec)
Default Minimum of DICONT and MICONT    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.8
Function Group Current Controller   EEPROM Yes
Short Description Rated Current

Description

This variable sets the required rated output continuous current. The adjustment is usually made to the standstill current for the connected motor. The value entered is limited to the lower of the rated current of the motor (MICONT) or the rated current of the amplifier (DICONT). This variable is used in the monitoring of the actual RMS current that is drawn. If the ICONT value is too low, the drive shows following errors and the torque is too low. If the ICONT value is too high, the motor can be thermally overloaded.