ASCII - Command O1    
Syntax Transmit O1 [data]    
Syntax Receive O1   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer8   CANBus Object Number 35AE (hex)
DIM -   PROFIBUS PNU 1774 (dec) IND = 1 (dec)
Range -   DPR 174 (dec)
Default -    
Opmode All   Data Type Bus/DPR Integer8
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.3
Function Group Digital I/O   EEPROM No
Short Description State of Digital Output 1

Description

The O1 command returns the state of the digital output 1 (0 = Low,1 = High).