ASCII - Command | SSIOUT | |||
Syntax Transmit | SSIOUT [Data] | |||
Syntax Receive | SSIOUT <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Integer8 | CANBus Object Number | 35F9 (hex) | |
DIM | - | PROFIBUS PNU | 1849 (dec) IND = 1 (dec) | |
Range | 0 .. 31 | DPR | 249 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer8 | |
Drive State | Disabled | Weighting | ||
Start Firmware | 1.20 | |||
Configuration | No | Last Change of this Object | 2.0 | |
Function Group | Feedback | EEPROM | Yes | |
Short Description | SSI Baud Rate |
Description
The SSIOUT command has different interpretations, depending on whether the SSI is configured as an output or an input at X5 (Drive 400 X4). 1. SSI output (GEARMODE != 7, ENCMODE = 2) SSIOUT = 0 baud rate 200 kbaud SSIOUT = 1 baud rate 1 Mbaud 2. SSI read-in (GEARMODE = 7, ENCMODE = 2) SSIOUT = number of data bits (25) |