| ASCII - Command | UVLTMODE | |||
| Syntax Transmit | UVLTMODE [Data] | |||
| Syntax Receive | UVLTMODE <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Integer8 | CANBus Object Number | 3617 (hex) | |
| DIM | - | PROFIBUS PNU | 1879 (dec) IND = 1 (dec) | |
| Range | 0, 1 | DPR | 279 (dec) | |
| Default | 1 | |||
| Opmode | All | Data Type Bus/DPR | Integer8 | |
| Drive State | Disabled + Reset (Coldstart) | Weighting | ||
| Start Firmware | 1.20 | |||
| Configuration | Yes | Last Change of this Object | 1.3 | |
| Function Group | Basic Setup | EEPROM | Yes | |
| Short Description | Undervoltage Mode | |||
Description
| The configuration variable UVLTMODE activates or inhibits the undervoltage monitoring of the amplifier. If the monitoring is activated (UVLTMODE=1), then the fault message F05 (undervoltage) is generated as soon a s the DC-bus voltage falls below the undervoltage threshold VBUSMIN and the output stage is eabled. |