| ASCII - Command | VBUSMAX | |||
| Syntax Transmit | VBUSMAX | |||
| Syntax Receive | VBUSMAX <Data> | Available in | ||
| Type | Variable ro | MMI | Yes | |
| ASCII Format | Integer32 | CANBus Object Number | 361C (hex) | |
| DIM | Volts | PROFIBUS PNU | 1884 (dec) IND = 1 (dec) | |
| Range | 450, 800, 900 | DPR | 284 (dec) | |
| Default | ||||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | ||
| Start Firmware | 1.20 | |||
| Configuration | No | Last Change of this Object | 1.3 | |
| Function Group | Amplifier | EEPROM | Yes | |
| Short Description | Maximum DC-bus Voltage | |||
Description
| The VBUSMAX parameter shows the value for the monitoring threshold for the fault message F02 (overvoltage). This fault message is generated as soon as the DC-bus voltage goes above the value of VBUSMAX. The VBUSMAX threshold depends on the setting for VBUSBAL. VBUSBAL=0 (230 V) VBUSMAX=450V VBUSBAL=1 (400 V) VBUSMAX=800V VBUSBAL=2 (480 V) VBUSMAX=900V |