ASCII - Command MJOG    
Syntax Transmit MJOG    
Syntax Receive MJOG   Available in  
Type Command   MMI Yes
ASCII Format Command   CANBus Object Number 3591 (hex)
DIM -   PROFIBUS PNU 1745 (dec) IND = 1 (dec)
Range -   DPR 145 (dec)
Default -    
Opmode 8   Data Type Bus/DPR -
Drive State Enabled   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group control commands   EEPROM No
Short Description Start Jog Mode

Description

MJOG starts the jog mode via the serial interface (OPMODE 8 only ). The velocity in the jog mode is taken from VJOG (with ± sign). Jog mode is defined as a continuous motion at a constant velocity. This type of operation is started without a reference point being set (without homing). The hardware limit switches are monitored. Software limit switches are only monitored if a reference point is set (the drive has been homed). Acceleration and deceleration ramps are taken from the settings for homing (see ACCR, DECR, and VJOG).